Skip to content
VORAFIREARCHITECTURAL FIRE Plan my fireplace
Menu

Store information

Water Vapor Fireplace Installation Guide

Plan a built-in water vapor fireplace around the room, the finished opening and the access needed for everyday care. Confirm the model-specific drawing before your builder starts fabrication.

800 mm model reference dimensions

The dimensions below come from the supplied 800 mm product drawing. They apply to that reference model, not every custom length.

Dimensions in millimeters
Part Reference dimension
Top flange 800 length × 250 depth
Body 750 length × 215 depth × 200 height
Clear opening 770 length × 230 depth
Internal recess depth At least 220

The overall flange covers the opening; do not use the flange size as the cutout size. Confirm tolerances, support and surrounding finishes on the final drawing.

VORAFIRE 800 mm model installation reference showing body, flange and opening dimensions
Illustrated planning reference based on the supplied drawing. Obtain the final project drawing before construction.

Power and water: confirm the ordered configuration

The source drawing specifies a reserved 220V outlet. Do not assume this applies to every destination or ordered unit, and do not infer supply voltage from plug shape. Confirm voltage, frequency, plug and electrical requirements for your exact order with the installer before connecting power.

Discuss whether your configuration uses manual filling or a planned water connection. Confirm water quality, connection, drainage and access requirements in the model instructions; do not add a permanent connection without the approved arrangement.

Ventilation, support and service access

  • Keep the supporting surface level and follow the drawing's requirements for surrounding materials.
  • The source drawing calls for non-combustible internal surrounding materials and bottom ventilation of approximately 0.02 m². Have the required opening arrangement confirmed for your project.
  • Keep the bottom air inlet and required ventilation clear of finishes, stored items and debris.
  • Provide access to the controls, water system and serviceable parts. Do not permanently seal the fireplace into the surround.

Installing below a television

A decorative flame does not establish that every TV-wall layout is suitable. Coordinate the fireplace instructions, television requirements, moisture management, ventilation, cables and access before approving the design. No universal TV clearance is specified here.

Read the TV-wall planning guide.

Before construction begins

  1. Choose the model, length, viewing arrangement and project location.
  2. Send room photos or drawings and identify the desired finished opening.
  3. Confirm the electrical and water configuration, ventilation, support and service access.
  4. Have your installer review the final drawing before cutting, enclosing or connecting the unit.

Request installation guidance for your project or view the linear fireplace.

Plan your fireplace with confidence